Eaton Moeller Switches

Eaton Moeller Switches

Home //Eaton Moeller Switches

Eaton Isolators Supplier

Eaton Isolators Supplier

Eaton moeller low-voltage switchgear offers a wide range of innovative UL® 1558 and UL® 891 designs providing safe, intelligent and flexible solutions to optimize operational performance enhance safety and save space. As a premier leader in power distribution equipment, Eaton serves oil and gas, data center, healthcare and industrial applications. 

RLA Electricals is one of the leading authorized Eaton switchgear Dealer, Eaton Moeller Switches supplier, Moeller Dealers in Kolkata market.

We have highly acknowledged organisation engaged in presenting a remarkable range of Eaton Moeller Switches.

Eaton Isolators Supplier Other Details:

The DILM IEC series includes non-reversing and reversing Eaton Moeller Switches Dealer in Kolkata as well as overload relays and accessories. Enclosed control options include metallic and non metallic enclosures with circuit breakers, and North American or European fuses.

We are one of the most reliable companies in this domain and are into offering Eaton Moeller Switches Dealer in Kolkata.

Other Details:

Manual Motor Control offers ideal space-saving and cost-saving solutions as Manual Starters, Manual Motor Disconnects, Group Motor Installations, and Self-Protected Manual Combination Starters. Manual motor starters and protectors provide protection against low level faults that fuses or circuit breakers on the branch circuit would ignore. In group motor installations more than one motor circuit is protected by a single branch circuit protective device

Eaton Isolators General Specification:

  • PRODUCT NAME : Eaton Moeller® switch
  • CATALOG NUMBER : 255895
  • MODEL CODE : P1-32/I2/SVB-SW/HI11-NA
  • EAN: 4015082558956
  • PRODUCT LENGTH/DEPTH : 115 mm
  • PRODUCT HEIGHT: 180 mm
  • PRODUCT WIDTH: 100 mm
  • PRODUCT WEIGHT: .483 kg
  • WARRANTY :Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.

CERTIFICATIONS

  • UL Listed
  • CSA Class No.: 3211-05
  • CSA
  • CSA-C22.2 No. 60947-4-1-14
  • CE
  • CSA File No.: 012528
  • IEC/EN 60947-3
  • UL File No.: E36332
  • VDE 0660
  • IEC/EN 60204
  • IEC/EN 60947
  • UL
  • UL 60947-4-1
  • UL Category Control No.: NLRV
  • CSA-C22.2 No. 9

Eaton Isolators SPECIFICATIONS

  • RATED OPERATIONAL CURRENT FOR SPECIFIED HEAT DISSIPATION (IN) 32 A
  • 10.11 SHORT-CIRCUIT RATING Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
  • RATED OPERATIONAL CURRENT (IE) AT DC-23A, 24 V 25 A
  • RATED OPERATIONAL POWER AT AC-3, 380/400 V, 50 HZ 13 kW
  • 10.4 CLEARANCES AND CREEPAGE DISTANCES Meets the product standard’s requirements.
  • MOUNTING METHOD Surface mounting
  • RATED BREAKING CAPACITY AT 220/230 V (COS PHI TO IEC 60947-3) 260 A
  • 10.2.3.1 VERIFICATION OF THERMAL STABILITY OF ENCLOSURES Meets the product standard’s requirements.
  • NUMBER OF SWITCHES 1
  • FITTED WITH: Black rotary handle and locking ring
  • DEGREE OF PROTECTION (FRONT SIDE) IP65
  • SHORT-CIRCUIT CURRENT RATING (BASIC RATING) i)5 kA, SCCR (UL/CSA) ii)110A, max. Fuse, SCCR (UL/CSA)
  • SHORT-CIRCUIT CURRENT RATING (HIGH FAULT) i)10 kA, SCCR (UL/CSA) ii)50 A, Class J, max. Fuse, SCCR (UL/CSA)
  • RATED OPERATIONAL CURRENT (IE) AT DC-23A, 120 V 12 A
  • RATED CONDITIONAL SHORT-CIRCUIT CURRENT (IQ) 80 kA
  • ACTUATOR TYPE Door coupling rotary drive
  • RATED MAKING CAPACITY UP TO 690 V (COS PHI TO IEC/EN 60947-3) 320 A
  • AMBIENT OPERATING TEMPERATURE – MAX 40 °C
  • ASSIGNED MOTOR POWER AT 115/120 V, 60 HZ, 1-PHASE 1 HP
  • FEATURES: i) Version as main switch ii) Version as maintenance-/service switch
  • ELECTRICAL CONNECTION TYPE OF MAIN CIRCUIT Screw connection
  • RATED BREAKING CAPACITY AT 500 V (COS PHI TO IEC 60947-3) 290 A
  • NUMBER OF POLES Three-pole
  • AMBIENT OPERATING TEMPERATURE – MIN -25 °C
  • 10.6 INCORPORATION OF SWITCHING DEVICES AND COMPONENTS Does not apply, since the entire switchgear needs to be evaluated.
  • RATED UNINTERRUPTED CURRENT (IU) 32 A
  • 10.2.6 MECHANICAL IMPACT Does not apply, since the entire switchgear needs to be evaluated.
  • 10.3 DEGREE OF PROTECTION OF ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
  • OPERATING FREQUENCY 1200 Operations/h
  • PRODUCT CATEGORY Main switch
  • NUMBER OF CONTACTS IN SERIES AT DC-23A, 48 V 2
  • RATED OPERATIONAL CURRENT (IE) AT DC-23A, 48 V 25 A

TERMINAL CAPACITY:

  • 2 x (1.5 – 6) mm², solid or stranded
  • 14 – 8 AWG, solid or flexible with ferrule
  • 1 x (1 – 4) mm², flexible with ferrules to DIN 46228
  • 1 x (1.5 – 6) mm², solid or stranded
  • 2 x (1 – 4) mm², flexible with ferrules to DIN 46228

  • NUMBER OF CONTACTS IN SERIES AT DC-23A, 24 V 1
  • HEAT DISSIPATION CAPACITY PDISS 0 W
  • ASSIGNED MOTOR POWER AT 460/480 V, 60 HZ, 3-PHASE 10 HP
  • ASSIGNED MOTOR POWER AT 200/208 V, 60 HZ, 1-PHASE 2 HP
  • RATED OPERATIONAL CURRENT (IE) AT AC-23A, 400 V, 415 V 32 A
  • 10.9.2 POWER-FREQUENCY ELECTRIC STRENGTH Is the panel builder’s responsibility.
  • OVERVOLTAGE CATEGORY III
  • DEGREE OF PROTECTION NEMA 12
  • ACTUATOR COLOR Black
  • RATED OPERATIONAL CURRENT (IE) AT AC-23A, 230 V 32 A
  • POLLUTION DEGREE 3
  • RATED OPERATIONAL POWER AT AC-23A, 500 V, 50 HZ 18.5 kW
  • RATED IMPULSE WITHSTAND VOLTAGE (UIMP) 6000 V AC
  • SWITCHING POWER AT 400 V 15 kW
  • VOLTAGE PER CONTACT PAIR IN SERIES 60 V
  • FUNCTIONS: i) STOP function ii) Interlockable
  • TIGHTENING TORQUE: i) 1.6 Nm, Screw terminals ii) 14.1 lb-in, Screw terminals
  • RATED OPERATIONAL POWER AT AC-3, 690 V, 50 HZ 15 kW
  • RATED OPERATIONAL CURRENT (IE) AT AC-3, 660 V, 690 V 14.7 A
  • TYPE Main switch
  • 10.2.2 CORROSION RESISTANCE Meets the product standard’s requirements.
  • 10.2.4 RESISTANCE TO ULTRA-VIOLET (UV) RADIATION UV resistance only in connection with protective shield.
  • 10.2.7 INSCRIPTIONS Meets the product standard’s requirements.
  • RATED OPERATIONAL CURRENT (IE) AT AC-3, 380 V, 400 V, 415 V 26.4 A
  • NUMBER OF AUXILIARY CONTACTS (NORMALLY OPEN CONTACTS) 1
  • SHOCK RESISTANCE 15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
  • ASSIGNED MOTOR POWER AT 230/240 V, 60 HZ, 3-PHASE 7.5 HP
  • AMBIENT OPERATING TEMPERATURE (ENCLOSED) – MIN -25 °C
  • RATED OPERATIONAL POWER AT AC-23A, 400 V, 50 HZ 15 kW
  • RATED OPERATIONAL CURRENT (IE) AT AC-23A, 500 V 30 A
  • RATED OPERATIONAL CURRENT (IE) AT DC-23A, 60 V 25 A
  • RATED OPERATIONAL POWER AT AC-23A, 220/230 V, 50 HZ 7.5 kW
  • 10.12 ELECTROMAGNETIC COMPATIBILITY Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
  • 10.2.5 LIFTING Does not apply, since the entire switchgear needs to be evaluated.
  • AMBIENT OPERATING TEMPERATURE (ENCLOSED) – MAX 40 °C
  • RATED OPERATIONAL CURRENT (IE) AT AC-21, 440 V 32 A
  • RATED OPERATIONAL VOLTAGE (UE) AT AC – MIN 690 V
  • 10.8 CONNECTIONS FOR EXTERNAL CONDUCTORS Is the panel builder’s responsibility.
  • SCREW SIZE M4, Terminal screw
  • ASSIGNED MOTOR POWER AT 575/600 V, 60 HZ, 3-PHASE 15 HP

LOAD RATING:

  • 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
  • 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
  • 2 x Iₑ (with intermittent operation class 12, 25 % duty factor)

  • RATED OPERATIONAL CURRENT (IE) AT AC-23A, 690 V 19.8 A
  • RATED PERMANENT CURRENT AT AC-21, 400 V 32 A
  • RATED OPERATIONAL POWER AT AC-3, 415 V, 50 HZ 13 kW

CLIMATIC PROOFING:

  • Damp heat, cyclic, to IEC 60068-2-30
  • Damp heat, constant, to IEC 60068-2-78

  • DEVICE CONSTRUCTION Complete device in housing
  • RATED BREAKING CAPACITY AT 400/415 V (COS PHI TO IEC 60947-3) 300 A
  • STATIC HEAT DISSIPATION, NON-CURRENT-DEPENDENT PVS 0 W
  • 10.9.3 IMPULSE WITHSTAND VOLTAGE Is the panel builder’s responsibility.
  • 10.5 PROTECTION AGAINST ELECTRIC SHOCK Does not apply, since the entire switchgear needs to be evaluated.
  • SAFE ISOLATION 440 V AC, Between the contacts, According to EN 61140
  • MOUNTING POSITION As required
  • SAFETY PARAMETER (EN ISO 13849-1) B10d values as per EN ISO 13849-1, table C.1
  • 10.13 MECHANICAL FUNCTION The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
  • RATED OPERATIONAL POWER AT AC-23A, 690 V, 50 HZ 15 kW
  • 10.9.4 TESTING OF ENCLOSURES MADE OF INSULATING MATERIAL Is the panel builder’s responsibility.
  • HEAT DISSIPATION PER POLE, CURRENT-DEPENDENT PVID 1.8 W
  • SWITCHING CAPACITY (AUXILIARY CONTACTS, GENERAL USE) 10A, IU, (UL/CSA)
  • RATED OPERATING VOLTAGE (UE) – MIN 690 V
  • UNINTERRUPTED CURRENT Rated uninterrupted current Iu is specified for max. cross-section.
  • EQUIPMENT HEAT DISSIPATION, CURRENT-DEPENDENT PVID 0 W
  • ASSIGNED MOTOR POWER AT 200/208 V, 60 HZ, 3-PHASE 3 HP
  • SUITABLE FOR:  i) Branch circuits, suitable as motor disconnect, (UL/CSA)ii) Ground mounting
  • RATED BREAKING CAPACITY AT 660/690 V (COS PHI TO IEC 60947-3) 250 A
  • ACCESSORIES Auxiliary contact or neutral conductor fitted by user.
  • NUMBER OF AUXILIARY CONTACTS (NORMALLY CLOSED CONTACTS) 1
  • RATED OPERATIONAL CURRENT (IE) AT DC-1, LOAD-BREAK SWITCHES L/R = 1 MS 32 A
  • 10.2.3.2 VERIFICATION OF RESISTANCE OF INSULATING MATERIALS TO NORMAL HEAT Meets the product standard’s requirements.
  • 10.2.3.3 RESIST. OF INSUL. MAT. TO ABNORMAL HEAT/FIRE BY INTERNAL ELECT. EFFECTS Meets the product standard’s requirements.
  • LIFESPAN, MECHANICAL 300,000 Operations
  • NUMBER OF CONTACTS IN SERIES AT DC-23A, 60 V 2
  • CONTROL CIRCUIT RELIABILITY 1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
  • RATED SHORT-TIME WITHSTAND CURRENT (ICW):  i)640 A, Contacts, 1 second ii) 0.64 kA
  • NUMBER OF AUXILIARY CONTACTS (CHANGE-OVER CONTACTS) 0
  • RATED OPERATIONAL VOLTAGE (UE) AT AC – MAX 690 V
  • 10.7 INTERNAL ELECTRICAL CIRCUITS AND CONNECTIONS Is the panel builder’s responsibility.
  • 10.10 TEMPERATURE RISE The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
  • SWITCHING CAPACITY (MAIN CONTACTS, GENERAL USE) 30 A, Rated uninterrupted current max. (UL/CSA)
  • NUMBER OF CONTACTS IN SERIES AT DC-23A, 120 V 3
  • RATED OPERATIONAL CURRENT (IE) AT AC-3, 500 V 23.4 A
  • ASSIGNED MOTOR POWER AT 230/240 V, 60 HZ, 1-PHASE 3 HP
  • RATED OPERATIONAL CURRENT (IE) AT AC-3, 220 V, 230 V, 240 V 26.4 A
  • RATED PERMANENT CURRENT AT AC-23, 400 V 32 A
  • SHORT-CIRCUIT PROTECTION RATING 50 A gG/gL, Fuse, Contacts
  • SWITCHING CAPACITY (AUXILIARY CONTACTS, PILOT DUTY): i) P600 (UL/CSA) ii) A600 (UL/CSA)
Contactors & Starters
Contactors & Starters
FAZ - MCB
FAZ - MCB
Single Tower
Signal Tower
Eaton Isolators Supplier
Motor Protective Circuit Breaker
Low Voltage Control Gear
Low Voltage Control Gear
MCB Supplier : Miniature Circuit Breaker
Miniature Circuit Breaker etc
Eaton Switchgear & Controlgear Price list
Eaton-MCB Price list
Eaton Switchgear & Controlgear Price list
Eaton Switchgear & Controlgear Price list